Abstract
Pressurizer plays an important role in controlling the pressure of the primary coolant system in pressurized water reactor (PWR) power plants. An accurate modelling of the pressurizer is needed to determine the pressure histories of the primary coolant system, and thus to successfully simulate overall PWR power plant behavior during transients. The purpose of this study is to develop a pressurizer model, and to assess its pressure transients using the TRACE code version 5.0. The benchmark of the pressurizer model was performed by comparing the simulation results with those from the tests at the Maanshan nuclear power plant. Four start-up tests of the Maanshan nuclear power plant are collected and simulated: 1) turbine trip test from 100% power; 2) large-load reduction at 100% power; 3) net-load trip at 100% power; and 4) net-load trip at 50% power. The simulation results are in reasonable agreement with the start-up tests, and thus the pressurizer model built in this study is successfully verified and validated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.