Abstract

In order to test new EFF-3 evaluations for 9Be, 56Fe, 58Ni and 60Ni, MCNP based analyses of the JAERI/FNS beryllium and iron TOF experiments and the IPPE Obninsk nickel TOF experiment were carried out. The analyses showed the followings results; EFF-3.0 56Fe (the previous version of EFF-3 56Fe) reproduces the measured neutron fluxes best. EFF-3.156Fe (the newest EFF-3 data of 56Fe) tends to overestimate the neutron flux from 5 to 10 MeV by 20 - 30 % and to underestimate it from 0.05 to 0.1 MeV by 20 %. For the newest 9Be, 58Ni and 60Ni EFF-3 data, the achieved accuracy is comparable to FENDL-1 and -2. Monte Carlo sensitivity and uncertainty calculations were also performed with a local version of the MCNP4A code. In general the uncertainties of the neutron flux calculated with EFF-3 data were smaller than those with FENDL-1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.