Abstract

It is important to have well-defined, reproducible methods to evaluate and compare newly developed air filtration equipment. To facilitate accurate assessment of air purification devices at the bench scale, an experimental system was designed, built, and documented to evaluate particulate removal efficiency (PRE) of air filtration devices based on principles used in ASHRAE standards. The system was then carefully characterized and used to evaluate PRE and total energy consumption of a novel acoustically enhanced impaction (AEI) air purification device. The AEI device demonstrated 99.998% PRE of 0.5–1.5 μm diameter KCl particles while causing a 120 Pa pressure drop and requiring a total of 3.0 W/l of air treated at indoor ambient conditions. A single element of the AEI device operated in a biological safety level 2 facility was then used to evaluate PRE of bioaerosol consisting of Bacillus cereus (BC) spores. PRE of BC was 99.86 ± 0.05% at indoor ambient temperature and pressure. This research describes th...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.