Abstract

The purpose of this study was to evaluate early results of below-knee bypass using fresh arterial allografts as arterial substitutes for limb salvage. From April 1991 to September 1993, we performed 28 below-knee bypass procedures using fresh arterial allografts in patients without a suitable autologous vein. Allografts were obtained by multiorgan harvesting from brain-dead subjects and preserved at 4 degrees C. Histologic examination of grafts was carried out. Secondary patency at 2 years calculated using the Kaplan-Meier method was 64% (confidence interval [CI] 45%-79%). No signs of graft deterioration or rejection were noted. These preliminary results are encouraging but long-term assessment is needed before expanding the range of application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.