Abstract

Most wind-related transmission line failures have been attributed to high intensity wind (HIW) events in the form of tornados and downbursts. In the current study, a numerical model is developed to investigate the performance of two guyed transmission lines under tornado wind loads. The F2 tornado wind field used in the study is based on a computational fluid dynamics (CFD) analysis that was developed and validated in previous studies. The tornado wind forces are calculated and are then incorporated into a three-dimensional nonlinear finite-element model that simulates both the towers and the conductors. The study investigates the effect of tornado loads on the structural performance of the two different guyed transmission line systems. The tornado locations leading to maximum internal forces in various members of the towers are identified and are considered as critical load cases. The nonlinear numerical model is then extended to study the progressive failure of the two transmission lines under the critical tornado load cases by varying the velocity of the tornado wind fields incrementally. The velocities at which a total collapse is predicted are identified for both towers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.