Abstract

This paper presents an evaluation of the structural behaviour of C-shaped angle shear connectors in composite beams, suitable for transferring shear force in composite structures. The results of the experimental programme, including eight push-out tests, are presented and discussed. The results include resistance, strength degradation, ductility, and failure modes of C-shaped angle shear connectors, under monotonic and fully reversed cyclic loading. The results show that connector fracture type of failure was experienced in C-shaped angle connectors and after the failure, more cracking was observed in those slabs with longer angles. On top of that, by comparing the shear resistance of C-shaped angle shear connectors under monotonic and cyclic loading, these connectors showed 8.8–33.1% strength degradation, under fully reversed cyclic loading. Furthermore, it was concluded that the mentioned shear connector shows a proper behaviour, in terms of the ultimate shear capacity, but it does not satisfy the ductility criteria, imposed by the Eurocode 4, to perform a plastic distribution of the shear force between different connectors along the beam length.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.