Abstract

The interest in the application of aluminium as a structural material has been greatly increased in recent years. However, behaviour of aluminium structures when exposed to fire is still relatively unresearched. Due to low melting temperature of the alloy, aluminium structures have low fire resistance, but aluminium is reflective and has surface emissivity which is more than two times lower compared to carbon steel. The Eurocode facing this issue (EN 1999-1-2) is based mainly on the Eurocode for structural fire design of steel structures (EN 1993-1-2) and therefore is not fully suitable for the application on aluminium structures. Here, an overview of the structural behaviour of aluminium structures exposed to fire is given through the comparison with steel structures. As a conclusion, priorities for a future research are highlighted, which should provide a base for the next generation of modern codes for structural fire design of aluminium structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.