Abstract

In order to define a representative waste composition for the experimental tests, the different streams of tritiated waste water which are expected to arise from the operation of the Wackersdorf reprocessing plant were indentified as well as their chemical and radiochemical composition. Results obtained by pretreatement applying distillation and the decontamination factors thus achieved will be presented, as well as data concerning the effects of the remaining contaminations in the distillate on the solid - polymer electrode and the generated hydrogen and oxygen flow of the electrolyser used operating in a neutral solution. Additional investigations were performed using a TELEDYNE electrolyzer which operates in an alkaline solution.