Abstract

Abstract In the present work the sensitization of the entire glow-curve is studied in 6 different quartz samples of Nigerian origin. The investigation was applied to the un-fired “as is” samples as well as to samples fired at 900°C for 1 hour following cooling to room temperature. The results showed that in the case of “as is” glow-curve is sensitized as a whole. There is an abrupt transition from the “natural” sensitivity without any previous heating and the artificial sensitivity induced after the first heating. The sensitization is growing up strongly to the 10th heating but to a lower rate. The sensitization factor of the TL glow-peak at “110°C” was found to be linearly correlated to the higher temperature TL peaks. In the case of annealed samples there is an initial increase between the sensitivity immediately after the end of annealing and after the first heating. As the number of heating is increased up to the 10th heating the sensitization is stabilized at a constant value. The results are discussed in the frame-work of existing models and implications of the sensitization effect in various applications, while some explanations are attempted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.