Abstract
Tensile tests and Finite Element (FE) analysis were conducted on the Thread-fixed One-side Bolts (TOBs) bolted T-stub with arc-shaped flange to steel tube in this paper. Critical parameters were determined as the thickness of tube wall, the outer diameter of steel tube, the thickness of arc-shaped flange, and the center angle between bolts. Test results revealed that the connection would encounter three typical failure modes, which were: failure mode 1, thread shear failure with yielding of tube wall; failure mode 2, complete yielding failure of tube wall; failure mode 3, thread shear failure with yielding of T-stub arc-shaped flange. Developed FE models are verified and used to analyze the yield line pattern of tube wall, the hoop stress distribution of cross-section of tube wall, and the shear acting on bolt shank. Based on the experimental and numerical results, preliminary analytical models and design methods are proposed to estimate the tensile yield strength of specimens under different failure modes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.