Abstract

In order to study the behavior of severe cavitation erosion occurring in a typical centrifugal pump with a high specific speed of Ns = 300 (m, m3/min, rpm), the high-frequency vibrations and noises due to such cavitation erosion are systematically investigated under various test conditions. The present erosion tests are carried out using three-dimensional impellers made of aluminum alloy. In a field where the flow rates as well as NPSH are low, the vibrating accelerations and the acoustic power sharply increase, so that severe erosion takes place in this field. A large difference in flow pattern is clearly observed with respect to the flow rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.