Abstract

The Hyougoken-Nanbu earthquake caused serious damage to reinforced concrete building structures. Investigation results indicated that most buildings which suffered serious structural damage were built before 1981, i.e. new modern buildings behaved well, because the current seismic design provisions were enforced by the ministry of construction in 1981. Typical damage patterns of reinforced concrete building structures were: (1) collapse of soft first story construction; (2) collapse of a mid-height story; (3) torsional failure resulting from eccentricities of stiffness and mass; (4) inadequate spacing and anchorage of transverse reinforcement; (5) shear failure of short columns; (6) fracture of re-bar splices by gas-pressure welding; (7) damage to separation joints and elevated corridors; and (8) damage to non-structural members (Preliminary Reconnaissance Report of the 1995 Hyougoken-Nanbu earthquake, Architectural Institute of Japan, 1995 (English version)).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.