Abstract
Based on a series of numerical calculations, the behavior of flow field in obstructed square buoyant vertical jet is summarized and analyzed. Based on the axial line velocity distribution, the flow after the disc can be divided into three regions, i.e., recirculation region, transitional region and self-similar region. The characteristic of self-similarity of upright velocity was validated. The three regions can also be distinguished based on the axial velocity. The axial velocity in self-similar region was found to obey the same law and the formula presented by introducing the velocity expression used by Chen and Rodi. The isolines of pressure on cross-sections of different heights were displayed and the production, expansion, breaking and disappearing of negative pressure regions were found.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.