Abstract

Mo is introduced into Si integrated circuits inadvertently during processing, often during Si epitaxial growth, high temperature furnace treatments, or ion implantation. Quantitative secondary ion mass spectrometry measurement of Mo concentrations in Si introduced by implantation is complicated by mass aliasing of and and by unexpected isotope ratios. Employing deep level transient spectroscopy depth profiling of implanted Mo in Si, we determine for the first time the diffusivity of Mo in Si, . We observe soluble Mo in Si at concentrations as high as , but present evidence that the solubility of Mo in Si is mediated by crystal defects and proximity of the surface. Mo does reduce carrier lifetime in Si, although it is not as an effective recombination center as Fe in Si. And in addition, Mo is not gettered to either epitaxial substrates or by high energy B implantation. Process engineers and circuit designers can expect little effect of Mo contamination on metal oxide semiconductor devices but can assume that trace Mo contamination may cause leakage current in bipolar devices. © 1999 The Electrochemical Society. All rights reserved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.