Abstract
Performance of RC interior beam-column joints at roof level is defined as the area needing research by ACI 352R-02. Because of a lack of research data on performance of this type of joints, two half scale interior beam-column connections with discontinuous column were designed in accordance with ACI 318-11 and ACI 352R-02 provisions. One of the specimens had wide beams and the other had conventional beams to compare their behavior. These specimens were tested under quasi-static cyclic loading. It became clear by the experiments that roof wide beam-column joint had lower strength compared to that of roof conventional beam-column joint. Both of the specimens had almost equal energy dissipation capacity. The conventional beam-column joint reached its expected capacity but wide beam-column joint did not reach its capacity. Moreover, wide beam-column joint had sufficient joint shear strength unlike conventional one. Therefore, joint shear requirements could be relaxed for roof wide beam-column joint. This relaxation must be reapproved by more tests to be advisable for design purposes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.