Abstract

This paper mainly researched the behavior of double fish plate connector between steel plate shear wall structure and steel frame. Four single fish plate connectors and four double fish plate connectors were tested under monotonic and cyclic loading. The hysteretic curves, skeleton curves, stiffness degradation curve and ductility coefficient were considered to study the behavior of two connections. Results showed that the behavior of double fish plate connector between steel plate shear walls and steel frame was better than single fish plate connector. Double fish plate connectors had higher bearing capacity, slower stiffness degradation, better ductility and better energy dissipation capacity. Constraint effect of steel plate shear walls became stronger, and the out-of-plane buckling failure of steel plate shear walls was delayed. Therefore, the double fish plate connectors could improve the behavior of connection between steel plate shear walls and steel frame, and provide a reference for engineering application

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.