Abstract

In this paper, behaviors of diesel spray injected along a wall were experimentally investigated. In order to clarify the wall effect on spray structure, the geometry of the wall and its relative position to the spray axis were varied. Structures of spray injected into a high-pressure atmosphere were recorded by high-speed photographs. Results shows that the asymmetrically large vortexes in the spray were induced by the wall effect, and the spray penetrating along the wall was deviated to the wall surface. This phenomenon is called the Coanda effect in the field of fluid dynamics. The growth orientation of spray was defined by image analysis. Maldistribution ratio of spray area was defined for the quantitative estimation of the spray deviation behavior. The spray deviating conditions such as the geometry of the wall and its relative position to the spray axis were fined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.