Abstract

This paper reports on a test containing 19 mixed-oxide fuel pins that was operated in the Experimental Breeder Reactor II (EBR-II) at peak cladding temperatures near 800{degrees} C. Two test pins that had been designed to fail at {approximately}5 at.% burnup and two low-burnup environmental pins failed and then were operated in the run beyond cladding breach mode for 22 days. Very high delayed neutron signals occurred during the irradiation of the test, and it was terminated as a result of high delayed neutron signals and evidence of plutonium in the coolant. Each of the four pins exhibited multiple breaches in the upper half of the fuel column. Measurements of fuel trapped on the filter section of a deposition sampler that was located above the test indicated that {approximately}2.7 g of fuel was lost during the irradiation. Postirradiation examination of the pins indicates that most of the fuel was lost from a single pin. The fuel loss resulted in an increase in the background delayed neutron signal but had no other deleterious long-term effect on the operation of the EBR-II.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.