Abstract

Laboratory model test results for the uplift of a shallow circular plate anchor embedded in a soft saturated clay are presented. For all tests the bottom of the anchor plate was vented to eliminate the mud suction force. The tests were divided into two categories: (1) short‐term tests to determine the variation of the net ultimate uplift capacity and hence the breakout factor with embedment ratio, and (2) creep tests with sustained uplift loads at varying embedment ratios. Based on the model test results, the variation with time, has been determined for the rate of strain of the soil located above the plate anchor. Empirical relationships for obtaining the rate of anchor uplift have been proposed.