Abstract
Reinforced concrete (RC) beams protrude from the ceiling, unless there is an infill wall beneath. Sometimes the construction of these beams is avoided due to aesthetic concerns, and instead a reinforcement arrangement with an equivalent bending moment capacity in the slab is made; this is named as a hidden beam. However, since such a design based only on strength can change the behavior to a great extent, the drawbacks of hidden beams were experimentally investigated. A total of fourteen half-scale specimens, including conventional T-beams and slabs with identical flexural capacities (hidden beams), were tested to failure under four-point loading. Reinforcement ratio and slab thickness were adopted as test parameters. The results indicated that hidden beams were able to achieve reference strengths after excessive (up to eight times larger) deformations, or they occasionally could never achieve these capacities. Experimental data were also compared with analytical deflection approaches.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.