Abstract
Presented in this paper are the results of a research project on the monitoring and assessment of the first link slab jointless bridge in the state of North Carolina. The structure was instrumented with a remote data acquisition system and monitored for over a year. In addition, a controlled load test was conducted in an effort to determine the demand on the link slab under known loads. A procedure for the limit-states design of a link slab system is also presented. Results indicate that while the crack size in the link slab exceeded the design level, the link slab fulfilled its function. Furthermore, the rotational demand from the large controlled loads as well as the traffic loads was similar in magnitude to the thermal induced rotations due to the difference in temperature between the top and bottom of the bridge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.