Abstract

The ejector pump has two main components, namely the electro-motor part and the mechanical part. The electro motor plays a vital role in the activity of draining sea water to the fresh water generator. The electro motor acts as a rotary driver in pump mechanics which has the working principle of converting electrical energy into mechanical energy. Control system and electro protection. The purpose of this research is to determine the cause of overload on a mechanical motor pump. The research was conducted by observation, namely direct observation of the pump which functions as an auxiliary machine. The results show that because the bearings experience excessive heat due to the connection at the center of the motor with the pump not being centered. Gland packing experiencing high speed events so that the shaft is difficult to rotate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.