Abstract

The sluice pier prototype vibration test conducted in China Shuhe Hydropower Station shows that the vibration response of the measuring points exhibits a special form of vibration, which demonstrates intermittency and impact under high-speed flood discharge excitation. The waveform envelope increases or decreases sharply with time and shows the formation of beat vibration. Research on the mechanism of this type of vibration is rare. To analyze the characteristics and causes of the obvious beat phenomenon in the testing of the sluice pier prototype, we conduct research in the following manner. First, mathematical models of synthetic signals are built to analyze the influences of initial phase difference, frequency ratio, and amplitude ratio and determine the beat vibration formation condition. Second, the stochastic subspace identification method is used to identify the operational modal parameters (including the vibration order, frequency, damping ratio, and mode of vibration) on the basis of the measured prototype dynamic response. Last, the internal causes of the beat vibration phenomenon are analyzed based on the combination of the formation conditions of apparent beat vibration. Results show that the vibration of Shuhe sluice pier is dominated by the first two frequency components. The vibration frequency ratio is between 0.928 and 0.962 and satisfies the necessary conditions of beat vibration. The amplitude ratio is between 0.66 and 1.63 and thus makes the waveforms of beat vibration highly evident.

Highlights

  • A sluice guarantees the safe operation of hydro-junctions during flood discharge periods

  • Influence of frequency ratio on the beat vibration of the sluice pier The modal identification results of the sluice pier on all working conditions showed that the sluice has three main vibration modes, in which the first-order frequency is in the range of 2.31–2.41 Hz, the second-order frequency is in the range of 2.45–2.55 Hz, and the third-order frequency is in the range of 3.76–4.41 Hz

  • The sluice pier of Shuhe Hydropower Station was used as an example to analyze the phenomenon of beat vibration in prototype vibration tests

Read more

Summary

Introduction

A sluice guarantees the safe operation of hydro-junctions during flood discharge periods. The formation conditions of beat vibration were determined by constructing a mathematical model, and the characteristics of such vibration were analyzed based on the results of modal parameters identified and measured on the sluice pier.

Results
Conclusion