Abstract

The vertical axis wind turbine generator is mainly used for small size wind turbine applications, and is independent of wind direction. Its rotating part (shaft unit) should be rotated by an extremely small torque so as to increase the generation efficiency. However, commercially available bearings are not necessarily suitable for the shaft unit because their static and dynamic load ratings are frequently larger than those required for the vertical axis wind turbine. As a result, the frictional force and the rotating torque of commercially available bearings are too large for the shaft unit to rotate lightly. In this study, through an experiment with an actual vertical axis wind turbine, the bearings used for the shaft unit are reviewed in accordance with IEC61400-2. The design of the shaft unit with the bearings having the most suitable load rating and frictional force for the vertical axis wind turbine is attempted. The newly designed shaft unit will be applied to the vertical axis wind turbine and will be tested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.