Abstract
This letter is concerned with the undrained bearing capacity of rectangular footings with various aspect ratios and embedment ratios in uniform clay. It covers thin plate foundations with low aspect ratios and high embedment depth with embedment ratio up to 150. The work is based on small strain finite element analysis (FEA). After verification of the FEA model against existing solutions of the bearing capacity factors of rectangular footings, a series of FEA results are obtained. Based on the FEA results, a simple formulation is proposed to calculate the bearing capacity factor for rectangle footing with different aspect ratio in any embedment depth, extending the existing solutions to cover a wider ranges of footing aspect ratios and embedment ratios.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.