Abstract

Abstract This study focused on the effect of trapped water on the bearing capacity of PVC pipe pile foundations. This research is divided into two models. The first model (pressure cap pipe pole) and the second model (open press pipe pole) each consist of four variations of PVC pipe diameters of 5.08 cm, 6.35 cm, 7.62 cm, and 10.16 cm (standard size PVC pipe diameter) with the same length of 30 cm. In the first type, all pipes are tightly closed at their upper ends. In the second type, all upper-end caps are given two holes, each with a diameter of 0.5 cm. Each pipe pile is alternately piled into soft soil with a moisture content of 98.8% is in a glass box measuring 120 cm x 20 cm x 60 cm. The test results of the load against decrease were analyzed using the Mazurkiwicks interpretation method. The bearing capacity of the end of the pole (Qp) along with the air trapped in the pipe pile (QA) can increase the carrying capacity of important poles compared to the carrying capacity of the pole side (Qs). PVC pipe poles belong to the floating pile foundation group due to the influence of air trapped inside the pile.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.