Abstract
The use of medical computed tomography (CT) systems for inspecting industrial materials and components such as ceramics, which have higher mass density and electron density than one encounters in medical applications, is subject to difficulties such as beam hardening and scattering. Beam hardening (BH) occurs when polychromatic radiation is preferentially attenuated by the material as a function of photon energy. The BH effect prevents accurate measurement of local material density and causes artifacts that lower the sensitivity of contrast and spatial resolution. Because BH problems cause significant complications in image interpretation, a great deal of effort has gone into addressing this problem for medical applications. However, little effort has gone into developing BH corrections for industrial materials such as ceramics. The purpose of this paper is to present a BH correction method that takes into account both the photon spectrum of the X-ray head and the properties of ceramic materials. Scattering contributions to image degradation will not be considered here.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.