Abstract

We present the results of two beam tests performed in July and September 1996 at CERN in order to study the behaviour of irradiated single- and double-sided silicon detectors from different manufacturers. All detectors had been irradiated with neutrons, up to a maximum fluence of 3.6×1013cm−2, and had reached type inversion. Signal-to-noise ratio, resolution and efficiency have been studied for different values of detectors bias voltage, operation temperature (ranging from −10°C to +20°C) and read-out pitch and, in some case, for different incidence angle of the incoming particle. The results are promising, since no dramatic deterioration of detector performances has been observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.