In order to realize a precise dose distribution in heavy-ion cancer therapy, high beam stability is required for the accelerator complex. Owing to load fluctuation caused by the upper ring, which is one of the two rings in HIMAC, current dips of ≈5–10 Hz were observed in the power supply for the bending/quadrupole magnet of the other lower ring. The parameters of the beam stability, such as the spill variation, the beam position, and the size, were adversely affected by the current dips. In order to suppress these current dips, we developed a new feed-forward system in the magnet power supply. We verified the performance of the feed-forward system by measuring the suppression of the current dips. We also performed beam experiments to measure the variation of the horizontal tune and the structure of the beam spill, which is slowly extracted by the resonance method. The experimental result showed that the current dips were successfully reduced by the system to Δ I/ I ∼ 10 −6. It was also confirmed that the horizontal tune and the spill structure could be stabilized by the current dip suppression.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.