Abstract

A button-type beam position monitor (BPM) has been designed and fabricated for the upgraded Pohang Light Source. The BPM consists of four buttons located symmetrically at top and bottom of the vacuum chamber. In the process of simulation, the Wakefield Simulator of CST Particle Studio is mainly used as the tool to calculate the wakefields and the electromagnetic fields. The BPM is tested by using a test stand to check its performance before installation. The calibration of BPM is also performed to check its position offsets and its sensitivities.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.