Abstract

We have developed 220 and 440-GHz cameras using microwave kinetic inductance detectors (MKIDs) for astronomical observations. The optical system of the MKID camera is based on double-slot antennas and extended hemispherical silicon lens arrays. The lens diameter is three times the target wavelength. The 220-GHz camera and the 440-GHz camera have 9 pixels and 102 pixels, respectively. The silicon lens array has been directly machined using a high-speed spindle on an ultra-precision machine. The shape fabrication error and the surface roughness of the top of the lens were typically less than 10 μm (peak-to-valley) and about 0.7 μm (rms), respectively. The beam patterns of the MKID camera were measured and are in good agreement with the calculations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.