Abstract
Beam momentum spread is a key parameter of the linac injector at the Xi’an Proton Application Facility (XiPAF), China. A momentum spread measurement method using multiple beam position monitors (BPM) was successfully developed recently at Tsinghua University, China. This work is an extension of the method. The original method requires at least three BPMs to perform the measurement, and the BPMs should be installed far from the accelerator exit, causing long measurement space and low BPM signals. The new method only needs two BPMs, and a much shorter measurement space is proposed for the low-current linac in this paper. The new method was successfully tested at XiPAF. The measured rms momentum spread at the Radio Frequency Quadrupole exit is (5.05 ± 0.06) × 10−3, which agrees well with the spectrometer measured value (5.09 ± 0.05) × 10−3.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.