Abstract
PurposeEstablish and compare two metrics for monitoring beam energy changes in the Halcyon platform and evaluate the accuracy of these metrics across multiple Halcyon linacs.MethodThe first energy metric is derived from the diagonal normalized flatness (FDN), which is defined as the ratio of the average measurements at a fixed off‐axis equal distance along the open profiles in two diagonals to the measurement at the central axis with an ionization chamber array (ICA). The second energy metric comes from the area ratio (AR) of the quad wedge (QW) profiles measured with the QW on the top of the ICA. Beam energy is changed by adjusting the magnetron current in a non‐clinical Halcyon. With D10cm measured in water at each beam energy, the relationships between FDN or AR energy metrics to D10cm in water is established with linear regression across six energy settings. The coefficients from these regressions allow D10cm(FDN) calculation from FDN using open profiles and D10cm(QW) calculation from AR using QW profiles.ResultsFive Halcyon linacs from five institutions were used to evaluate the accuracy of the D10cm(FDN) and the D10cm(QW) energy metrics by comparing to the D10cm values computed from the treatment planning system (TPS) and D10cm measured in water. For the five linacs, the D10cm(FDN) reported by the ICA based on FDN from open profiles agreed with that calculated by TPS within –0.29 ± 0.23% and 0.61% maximum discrepancy; the D10cm(QW) reported by the QW profiles agreed with that calculated by TPS within –0.82 ± 1.27% and –2.43% maximum discrepancy.ConclusionThe FDN‐based energy metric D10cm(FDN) can be used for acceptance testing of beam energy, and also for the verification of energy in periodic quality assurance (QA) processes.
Highlights
Beam energy metrics for the acceptance and quality assurance of Halcyon linear accelerator Song Gao Mikhail A Chetvertkov Bin Cai Abhishek Dwivedi Dimitris Mihailidis See page for additional authors.
Follow this and additional works at: https://digitalcommons.wustl.edu/open_access_pubs
Song Gao, Mikhail A Chetvertkov, Bin Cai, Abhishek Dwivedi, Dimitris Mihailidis, Xenia Ray, Tucker Netherton, Laurence E Court, William E Simon, and Peter A Balter
Summary
Beam energy metrics for the acceptance and quality assurance of Halcyon linear accelerator Song Gao Mikhail A Chetvertkov Bin Cai Abhishek Dwivedi Dimitris Mihailidis See page for additional authors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.