Neutral beam attenuation has been investigated by the beam emission diagnostic system at LHD which consists of a quartz optical fiber, leading to a spectrometer and an ICCD detector. The spectral resolution and the reciprocal dispersion are 0.21 nm and 1.4 nm/mm, respectively. The behavior of the beam-stopping cross-section derived from the beam emission is consistent with that of the cross-section from the Atomic Data and Analysis Structure (ADAS) database. The intensity of the beam emission decreases with increasing stopping cross-section from the use of heavy ions in a discharge. We have also observed that the measured cross-section of the hydrogen is larger than that of the ADAS calculation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Fusion Science and Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.