A 325 MHz interdigital H-mode drift tube linac (IH-DTL), which is aimed at proton medical facilities, has been proposed and developing at Tsinghua University. The proton beam can be accelerated from 3 MeV to 7 MeV and the peak current of the beam at the exit of the cavity is about 15 mA. A KONUS dynamics without focusing element is applied in this cavity. The co-iteration of dynamics simulation and RF simulation is done. The process and result of the design is presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.