Abstract
Operando powder X-ray diffraction (PXRD) is a widely employed method for the investigation of structural evolution and phase transitions in electrodes for rechargeable batteries. Due to the advantages of high brilliance and high X-ray energies, the experiments are often carried out at synchrotron facilities. It is known that the X-ray exposure can cause beam damage in the battery cell, resulting in hindrance of the electrochemical reaction. This study investigates the extent of X-ray beam damage during operando PXRD synchrotron experiments on battery materials with varying X-ray energies, amount of X-ray exposure and battery cell chemistries. Battery cells were exposed to 15, 25 or 35 keV X-rays (with varying dose) during charge or discharge in a battery test cell specially designed for operando experiments. The observed beam damage was probed by µPXRD mapping of the electrodes recovered from the operando battery cell after charge/discharge. The investigation reveals that the beam damage depends strongly on both the X-ray energy and the amount of exposure, and that it also depends strongly on the cell chemistry, i.e. the chemical composition of the electrode.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.