Abstract

An ambient vibration test was conducted for the pedestrian bridge that links the City University (CityU) of Hong Kong and the adjacent subway station. In this test, 100 locations forming a net of measurement were selected. Due to the limited number of sensors available, 10 setups were designed to cover all the degrees of freedom (dofs) of interest. A recently developed Bayesian method incorporating multiple setups was used to analyze the collected data. Besides the most probable values (MPVs) of modal parameters, the associated posterior uncertainty was also calculated analytically without resorting to the finite difference method. Six modes were identified, including some local modes of specified spans and global modes, and compared with those identified in a previous study. The difficulty encountered in the field test is discussed, along with some interesting features. Practical interpretation of the statistics of modal parameters calculated from frequentist and Bayesian context is also discussed. After the field test, a lift was installed between the ground and the bridge deck, which changed the modal properties of the original structure. This study provides a baseline of the dynamic characteristics of the original structure for future safety assessment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.