Abstract

This paper presents a method for calculating eddy current loss in permanent magnets of a surface permanent magnet (SPM) motor based on electric and magnetic networks. First, an electric network model to calculate the eddy current loss is indicated. Next, a reluctance network analysis (RNA) model of the SPM motor considering the rotor rotation is presented. The eddy current losses in the magnet of the SPM motor from no load to full load conditions are calculated by the RNA model and electric network model. The proposed model can be taken into account the effect of carrier harmonics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.