Abstract

Mildly symptomatic heart failure (HF) patients were shown to derive substantial clinical benefit from cardiac resynchronization therapy with defibrillator (CRT-D) in Multicenter Automatic Defibrillator Implantation Trial in Cardiac Resynchronization Therapy. However, the relationship between functional capacity (FC) and CRT-D benefit in the trial was not assessed. To evaluate the association between FC and response to CRT-D in Multicenter Automatic Defibrillator Implantation Trial in Cardiac Resynchronization Therapy. We evaluated the association between preimplantation FC and the benefit of CRT-D in reducing the risk of HF or death in Multicenter Automatic Defibrillator Implantation Trial in Cardiac Resynchronization Therapy. Functional status was assessed by a 6-minute walk test (6MWT), dichotomized at the median value as poor (<350 m) or good (≥350 m). Implantable cardioverter-defibrillator-only patients with a poor FC had an adjusted 73% increased risk for HF or death (P <.001) and a 2.4-fold (P = .001) increased risk for all-cause mortality. CRT-D therapy was associated with 63% (P <.001) and 44% (P <.001) reductions in the risk of HF or death among left bundle branch block patients with a poor FC and a good FC, respectively (P for interaction = .10). Among left bundle branch block patients with a poor FC, CRT-D was also associated with a significant reduction in the risk of all-cause mortality (hazard ratio 0.52; P = .015) whereas the survival benefit of CRT-D was not observed among those who had a higher FC at enrollment (hazard ratio 1.01; P = .98; P for interaction = .10). Poor FC is a strong independent predictor for mortality and HF events in patients with mildly symptomatic HF. Left bundle branch block patients with poor baseline FC derive a pronounced benefit from CRT-D, manifest by a significant reduction in mortality.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call