Abstract
Conventional isolation systems may induce an excessive response in near-fault earthquakes. A new short time Fourier transformation (STFT) control algorithm for variable friction dampers (VFD) is developed to improve the performance of base isolation buildings in near-fault earthquakes. The STFT controller varies the clamping force in the VFD damper to achieve the response reduction. In addition, the STFT algorithm is implemented analytically on a multi degree of freedom system (MDOF) with laminated rubber bearings and variable friction dampers in Simulink environment. Three types of earthquakes representing a wide variety of ground motions are considered as the ground excitations in the simulation. The numerical show that, compared with conventional isolation systems, the semi-active isolation system controlled by the STFT algorithm can reduce the excessive response in near-fault earthquakes effectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.