Abstract

The effect of swift heavy ion (72.5 MeV 58Ni 6+) irradiation on Au/n-GaAs Schottky barrier characteristics is studied using in situ current–voltage measurements. Diode parameters are found to vary as a function of ion irradiation fluence. The Schottky barrier height (SBH) is found to be 0.55(±0.01) eV for the as deposited diode, which decreases with ion irradiation fluence. The SBH decreases to a value of 0.49(±0.01) eV at the highest ion irradiation fluence of 5 × 10 13 ions cm −2. The ideality factor is found to be 2.48 for unirradiated diode, and it increases with irradiation to a value of 4.63 at the highest fluence. The modification in Schottky barrier characteristics is discussed considering the energy loss mechanism of swift heavy ion at the metal–semiconductor interface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.