Abstract

ABSTRACTObjective: To assess whether Bare Spot is previously displaced by proportion (MEASURE BP-A × 1.25/MEASURE BP-P = 1). Methods: 35 patients with surgical indication for rotator cuff injury repair were evaluated. The distances from the Bare Spot to the anterior edge of the glenoid cavity (BS-A) and to the posterior edge (BS-P) were measured by arthroscopy and computed tomography with three-dimensional reconstruction of the scapula. Results: The distance from the Bare Spot to the anterior border (BS-A tc) was 11.6 mm with a median 12 mm; The distance to the posterior border (BS-P tc) was on average 15.5 mm with a median 15 mm. The distances from BS to anterior cavity edge measured by arthroscopy were on average (BS-A video) 12.25 mm with a median of 12 mm, and from BS to posterior edge (BS-P video) 16.25 mm on average with median 16 mm (p < 0.005). Conclusion: Bare Spot is displaced anteriorly at a proportion of 40% of the anterior margin and 60% of the posterior margin. Level of Evidence II - Development of diagnostic criteria on consecutive patients (with universally applied reference “gold standard”).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call