In this paper the design of a controller for a relay controlled second order nonlinear unstable plant with fourth order nonlinearity is considered. The task of the controller is the simultaneous reduction of output and output derivative to zero with the input being at zero. It is established that, if the initial values of error and error derivative fall in a “controllable region”, it is possible to reduce error and error derivative to zero simultaneously and in the shortest possible time with at most one switching reversal of the relay. It is also shown that, through simple transformation of error and error derivative, the equation of the switching curve can be made independent of the constant gain of the plant, as well as the coefficient of the nonlinear term.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.