Abstract

The use of common dc-link parallel three-phase PWM converters without isolating transformers will cause zero-sequence circulating current problem. Previous works have proven that the circulating current is mainly affected by zero vectors employed in each PWM cycle. This paper proposes a novel method to suppress the circulating current. Detailed analysis is presented on the causes of zero-sequence circulating current based on a derived average model. A zero vectors feed-forward control strategy in combination with traditional PI control method is proposed to reject disturbances in zero-axis current system. In addition, a dual current sampling and dual PWM duty ratio update (DSDU) scheme is used to expand the bandwidth of zero-axis current loop. As a result, better circulating current suppression performance can be achieved in different filter inductance and converter output currents condition. Compared with the PI control method, the converters operated in parallel can be switched on and switched off separately with small current impact. Experimental results confirm the performance and effectiveness of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.