Abstract
Although the use of inferior vena cava (IVC) filters has expanded, complications have led to the recommendation to remove all unnecessary filters. Several techniques exist to aid in retrieving irretrievable IVC filters. The balloon-assisted retrieval technique has previously been described to aid in cases of an embedded hook. This report describes an alternative use of the balloon-assisted technique, specifically to aid in the retrieval of Greenfield IVC filters in cases of strut perforation of the cava wall. This technique was successfully performed in six out of six attempted cases with no associated complications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.