Abstract
This paper proposes a new modulation strategy with balanced power device currents for the full-bridge three-level dc/dc converter. The proposed modulation strategy has two working patterns, which cannot only realize zero-voltage switching (ZVS) but also satisfy the wide input voltage range. More significantly, the two working patterns of the proposed strategy can balance the currents both among the power switches and clamping diodes in comparison with the conventional control strategies which cause current imbalances among the power switches and clamping diodes. Consequently, the proposed strategy can balance the thermal stresses among the power switches and clamping diodes, which would, thus, improve the converter's reliability. Finally, the experimental results, obtained using a built 1.5-kW experimental prototype, verify almost zero current difference and zero thermal-stress difference among the inner power switches, outer power switches, and clamping diodes under the proposed strategy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.