Abstract
This study aims to analyse the relationship between the incidence of bad splits and the surgical tools adopteded to perform bilateral sagittal split ramus osteotomy (BSSRO).BSSROs performed by the same experienced surgeon period were reviewed, retrospectively. The patients were divided into three groups according to the surgical instrument used to perform the osteotomy: a Lindemann burr, reciprocating saw or piezosurgery. Among the 1120 BSSROs performed, 5 bad fractures were detected during the observation period: 3 among patients operated with the Lindemann burr (0.8%) and 2 among those operated with a reciprocating saw (0.5%). There was no significant correlation between the bad split rate and age and gender of the patients, the type of malocclusion or the type of instrument used to perform the osteotomy.Within the limitations of the study it seems that the the choice of the osteotomy tool for BSSRO does not influence the rate of bad fractures and, therefore, the selection of the osteotmy tool should be left to the discretion of the surgeon.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.