Abstract

Wild type T4 bacteriophage and recombinant T4 bacteriophages displaying biotin binding peptide (BCCP) and cellulose binding module (CBM) on their heads were immobilized on nano-aluminum fiber-based filter (Disruptor™), streptavidin magnetic beads and microcrystalline cellulose, respectively. Infectivity of the immobilized phages was investigated by monitoring the phage-mediated growth inhibition of bioluminescent E. coli B and cell lysis using bioluminescent ATP assay. The results showed that phage immobilization resulted in a partial loss of infectivity as compared with the free phage. Nevertheless, the use of a biosorbent based on T4 bacteriophage immobilized on Disruptor™ filter coupled with a bioluminescent ATP assay allowed simultaneous concentration and detection of as low as 6 × 10 3 cfu/mL of E. coli in the sample within 2 h with high accuracy (CV = 1–5% in log scale). Excess of interfering microflora at levels 60-fold greater than the target organism did not affect the results when bacteriophage was immobilized on the filter prior to concentration of bacterial cells.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.