Abstract

Many developing countries, including Ghana, are water stressed. As such, farmers, particularly those in urban areas, have adopted the use of wastewater for irrigation. This study evaluated the bacteriological water quality of the wastewater used for irrigation in the vegetable farms at Korle-Bu Teaching Hospital (KBTH), Accra Metropolis, Ghana. In all, 40 wastewater samples were collected and analysed bacteriologically using the total aerobic plate count method. The isolated bacteria were identified biochemically using Bergey's manual for determinative bacteriology. Mean total bacterial colony count values in the range of 2.75-4.44 × 105 CFU/100 mL were isolated which far exceeds values of 1 × 103/100 mL recommended by the World Health Organization (WHO) for unrestricted irrigation of crops likely to be eaten raw. Enterobacter cloacae (51.4%), Klebsiella sp. (24.1%), Pseudomonas aeruginosa (11.3%), Salmonella typhi (10.6%), Escherichia coli (2.2%) and Proteus sp. (0.4%) were the predominant bacteria isolated. Growers should use treated wastewater for farming while processors and consumers should minimize contamination risks of produce from the vegetable farms/garden to the plate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.