Abstract

The effect of laser radiation on Staphylococcus aureus 6571 (Oxford strain) was studied with high-power Nd:YAG laser radiation between 50 and 300 W. A range of laser pulse repetition frequencies (PRF) from 5 to 30 Hz, with a combination of pulse energies from 2 to 30 J were applied; this covered a range of energy densities from 800 to . The area of inactivation of S. aureus, lawned on nutrient agar plates, was quantified as a function of energy density and exposure time. The shortest exposure time which produced an area of inactivation equal to 50% of the beam area was achieved at a PRF of 30 Hz, pulse energy of 10 J, and with an exposure time of 10.75 s; this was equivalent to an applied energy density of . No bacterial inactivation was observed at relatively low-power settings for PRF, pulse energies and exposure time of: 20 Hz, 3 J and 34 s; 25 Hz, 2 J and 45 s and 30 Hz, 2 J and 35 s, respectively. These results shows that pulse energy, PRF and exposure time are important criteria when considering inactivation of micro-organisms by laser radiation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.